550 bhp fire tube steam boiler manufacturers
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
In most cases ten minutes of water should be readily available for your boiler. One boiler horsepower = 34.5 lbs/hr of steam (or water) from and at 212o F. We also know that one-gallon of water weighs 8.37 lbs. To calculate the storage tank needed use the following formula: BHP X 34.5 ÷ 8.337 lbs ÷ 60 min. X 10 = minimum useable capacity in Get Price
A surface condenser serving a 50,000 kW steam turbo-generator unit receives exhaust steam at the rate of 196,000 kg/hr. Vacuum in condenser is 702 mm. Hg. Sea. water for cooling enters at 29 and leaves at 37.5 C . For steam turbine condenser, manufacturers consider 950 Btu/lb of steam turbine condensed as heat given up to cooling water Get Price
In a boiler making superheated steam, furnace exit temperatures must be known accurately in order to design the convection section. Case history of a 20 gph fire tube hot water boiler As found Reset to specifi- cations draft 0.22" 0.06" CO 2 10.5 13.0 Smoke # 6 2 soot much trace tiertiary air vary with burner manufacturers. One Get Price
A surface condenser serving a 50,000 kW steam turbo-generator unit receives exhaust steam at the rate of 196,000 kg/hr. Vacuum in condenser is 702 mm. Hg. Sea. water for cooling enters at 29 and leaves at 37.5 C . For steam turbine condenser, manufacturers consider 950 Btu/lb of steam turbine condensed as heat given up to cooling water Get Price
: 50 mt: deck: 3200 mt: bitumen cgo capacity in tanks: 3200 m3 @100 %, 3092.48 m3 @98%: cargo heating system: 2 – boilers- thermo oil heated type (cargo temp 150°c) cargo pumps: 2x90 tons/ hour: bow ramp width : 12.5 mtr wide x 10 mtr long (100 tonnes load) accomodation : 15 crew plus owner suit (fully air conditioned) main engineGet Price
In a boiler making superheated steam, furnace exit temperatures must be known accurately in order to design the convection section. Case history of a 20 gph fire tube hot water boiler As found Reset to specifi- cations draft 0.22" 0.06" CO 2 10.5 13.0 Smoke # 6 2 soot much trace tiertiary air vary with burner manufacturers. One Get Price
Hurst Boiler, Inc. is the leading manufacturer of gas, oil, wood, coal, solid fuel, solid waste, biomass and hybrid fuel-fired steam and hot water boilers. Hurst …Get Price